A gel that runs badly rarely announces why. The band smears, the ladder looks crooked, the small fragment disappears off the bottom, and the temptation is to blame the sample. In most cases the cause is upstream: the wrong agarose concentration, a buffer that has been reused too many times, or a gel poured too hot and set unevenly.

At JW RESEARCH SUPPLY, we supply agarose, buffer concentrates, ladders, loading dyes, stains and casting accessories to molecular biology, diagnostics and teaching laboratories across Singapore. This guide sets out the consumable specifications that actually change a gel result.

Consumables Compared

Item Typical Specification Role Points to Watch
Agarose, standard Molecular biology grade, EEO ≤ 0.15 Routine DNA and RNA gels Check moisture content and lot-to-lot gel strength
Agarose, low melting Gelling 26 – 30 °C, melting 65 °C In-gel extraction, enzymatic reactions Lower gel strength; handle carefully
TAE concentrate 50x, pH 8.0 – 8.3 Routine DNA electrophoresis Low buffering capacity; replace for long runs
TBE concentrate 10x, pH 8.0 – 8.3 Small fragments, longer runs Borate carryover can inhibit later steps
DNA ladder 100 bp, 1 kb or custom range Size reference and yield estimate Heat and freeze-thaw degrade the ladder
Loading dye 6x with bromophenol blue or xylene cyanol Tracks loading and monitors the run Dye front does not equal fragment size
Precast gel 0.8 – 2% agarose, single use cassette Fast routine checks, teaching labs Check expiry and storage temperature

Specification Reference

Parameter Typical Range What It Affects
Agarose concentration 0.5% – 3.0% (w/v) Resolution window and run speed
Gel thickness 3 – 10 mm Well capacity and handling strength
Well count and volume 8 – 20 wells; 10 – 50 µL Samples per run and loading comfort
Applied voltage 5 – 10 V/cm of gel length Resolution; excessive voltage causes smearing
Buffer volume Just covers the gel by 2 – 5 mm Heat dissipation and current stability
EEO rating ≤ 0.15 for standard molecular biology agarose Electroendosmosis and band sharpness
Gel strength ≥ 1,200 g/cm² at 1% for standard grades Whether the gel survives loading and handling
Stain Ethidium bromide or safer alternatives Sensitivity, safety and waste handling

Matching Agarose Concentration to Fragment Size

Concentration is the single most useful variable. A 0.8 percent gel separates fragments from about 800 bp to 10 kb cleanly; a 2 percent gel resolves fragments below 500 bp that would run together on a looser gel. If a band is faint and diffuse at the bottom of the gel, the fragments are probably smaller than the gel can resolve rather than absent.

Pour the gel at a consistent thickness and let it set undisturbed. A gel poured too hot, or moved while setting, produces a wedge that tilts every band. Use the same tray and comb combination each time so that well depth and spacing stay constant between runs.

Buffer Practice

Prepare working buffer from a concentrate with distilled water and record the date on the bottle. Reusing running buffer is acceptable for a small number of short runs, but the ions deplete and the pH drifts, which shows up as slow migration and fuzzy bands. For long or high-voltage runs, recirculate the buffer or replace it.

Keep TAE and TBE systems separate. Residues of borate from TBE can inhibit ligation and sequencing reactions if glassware or tanks are shared without rinsing. If your workflow includes both, label tanks clearly and rinse with distilled water between uses.

Loading, Ladders and Documentation

Safety and Waste

Ethidium bromide is a mutagen and must be handled with gloves, in a designated area, with its own waste stream. Safer alternatives reduce the hazard but still require disposal according to your institution's procedure. Agarose gels containing stain should never go into general waste or down a sink.

Electrophoresis tanks use direct current at potentially hazardous voltage. Check leads and lid interlocks before each run, and never open a tank while the power supply is on.

Ordering Checklist

Tell us your fragment range, throughput and buffer preference, and we will propose a consumable list with pack sizes that match your weekly gel count, delivered across Singapore.