Gel Electrophoresis Supplies Singapore
A gel that runs badly rarely announces why. The band smears, the ladder looks crooked, the small fragment disappears off the bottom, and the temptation is to blame the sample. In most cases the cause is upstream: the wrong agarose concentration, a buffer that has been reused too many times, or a gel poured too hot and set unevenly.
At JW RESEARCH SUPPLY, we supply agarose, buffer concentrates, ladders, loading dyes, stains and casting accessories to molecular biology, diagnostics and teaching laboratories across Singapore. This guide sets out the consumable specifications that actually change a gel result.
Consumables Compared
| Item | Typical Specification | Role | Points to Watch |
|---|---|---|---|
| Agarose, standard | Molecular biology grade, EEO ≤ 0.15 | Routine DNA and RNA gels | Check moisture content and lot-to-lot gel strength |
| Agarose, low melting | Gelling 26 – 30 °C, melting 65 °C | In-gel extraction, enzymatic reactions | Lower gel strength; handle carefully |
| TAE concentrate | 50x, pH 8.0 – 8.3 | Routine DNA electrophoresis | Low buffering capacity; replace for long runs |
| TBE concentrate | 10x, pH 8.0 – 8.3 | Small fragments, longer runs | Borate carryover can inhibit later steps |
| DNA ladder | 100 bp, 1 kb or custom range | Size reference and yield estimate | Heat and freeze-thaw degrade the ladder |
| Loading dye | 6x with bromophenol blue or xylene cyanol | Tracks loading and monitors the run | Dye front does not equal fragment size |
| Precast gel | 0.8 – 2% agarose, single use cassette | Fast routine checks, teaching labs | Check expiry and storage temperature |
Specification Reference
| Parameter | Typical Range | What It Affects |
|---|---|---|
| Agarose concentration | 0.5% – 3.0% (w/v) | Resolution window and run speed |
| Gel thickness | 3 – 10 mm | Well capacity and handling strength |
| Well count and volume | 8 – 20 wells; 10 – 50 µL | Samples per run and loading comfort |
| Applied voltage | 5 – 10 V/cm of gel length | Resolution; excessive voltage causes smearing |
| Buffer volume | Just covers the gel by 2 – 5 mm | Heat dissipation and current stability |
| EEO rating | ≤ 0.15 for standard molecular biology agarose | Electroendosmosis and band sharpness |
| Gel strength | ≥ 1,200 g/cm² at 1% for standard grades | Whether the gel survives loading and handling |
| Stain | Ethidium bromide or safer alternatives | Sensitivity, safety and waste handling |
Matching Agarose Concentration to Fragment Size
Concentration is the single most useful variable. A 0.8 percent gel separates fragments from about 800 bp to 10 kb cleanly; a 2 percent gel resolves fragments below 500 bp that would run together on a looser gel. If a band is faint and diffuse at the bottom of the gel, the fragments are probably smaller than the gel can resolve rather than absent.
Pour the gel at a consistent thickness and let it set undisturbed. A gel poured too hot, or moved while setting, produces a wedge that tilts every band. Use the same tray and comb combination each time so that well depth and spacing stay constant between runs.
Buffer Practice
Prepare working buffer from a concentrate with distilled water and record the date on the bottle. Reusing running buffer is acceptable for a small number of short runs, but the ions deplete and the pH drifts, which shows up as slow migration and fuzzy bands. For long or high-voltage runs, recirculate the buffer or replace it.
Keep TAE and TBE systems separate. Residues of borate from TBE can inhibit ligation and sequencing reactions if glassware or tanks are shared without rinsing. If your workflow includes both, label tanks clearly and rinse with distilled water between uses.
Loading, Ladders and Documentation
- Ladder choice: pick a ladder that brackets your expected fragment sizes, and load the same amount on every gel so band intensity is comparable.
- Ladder storage: aliquot to avoid repeated freeze-thaw; a ladder that has been thawed ten times gives uneven bands.
- Loading dye: the dye front tells you how far the run has progressed, not how large the fragments are; do not stop the run purely on colour.
- Staining: follow the stain manufacturer's concentration and time, and image within a consistent window so results are comparable across gels.
- Documentation: capture an image with the ladder visible and record voltage, time, gel percentage and buffer lot.
Safety and Waste
Ethidium bromide is a mutagen and must be handled with gloves, in a designated area, with its own waste stream. Safer alternatives reduce the hazard but still require disposal according to your institution's procedure. Agarose gels containing stain should never go into general waste or down a sink.
Electrophoresis tanks use direct current at potentially hazardous voltage. Check leads and lid interlocks before each run, and never open a tank while the power supply is on.
Ordering Checklist
- Fragment size range and required resolution
- Agarose grade and concentration
- Buffer system: TAE or TBE, concentrate volume
- Ladder range and format
- Precast gels or in-house casting supplies
- Stain type and waste disposal route
Tell us your fragment range, throughput and buffer preference, and we will propose a consumable list with pack sizes that match your weekly gel count, delivered across Singapore.